DUAL PLATE  NRV FOR FIRE LINE
DUAL PLATE  NRV FOR FIRE LINE

DUAL PLATE NRV FOR FIRE LINE

Price 1000 INR/ Piece

MOQ : 100 Pieces

DUAL PLATE NRV FOR FIRE LINE Specification

  • Coating Type
  • Fusion Bonded Epoxy coated
  • Coverage Area
  • Pipe-specific, typically matched to specified diameter
  • Mounting Type
  • In-line, wafer-type between flanges
  • Features
  • Low pressure drop, easy installation, corrosion-resistant, spring-loaded plates for quick shutoff, zero leak sealing
  • Working Temperature
  • -10C to 80C
  • Operating Pressure
  • Up to 16 Bar
  • Connectivity Type
  • Flanged, Wafer connection
  • Fire Extinguisher Type
  • Not Applicable (pipe flow control, not extinguisher)
  • Installation Type
  • Horizontal or Vertical pipeline mounting
  • Shape
  • Cylindrical (Wafer form)
  • Fire Class
  • Suitable for Class A, B, C fire protection pipework
  • Voltage
  • Not required (mechanical operation)
  • Technology
  • Dual Plate (Wafer Type) Non-Return Valve
  • Control Type
  • Automatic flow-dependent
  • Application
  • Fire Line, Fire-fighting systems, Water and fire sprinkler pipelines
  • Max Flow Rate
  • Up to 5000 LPH (varies by diameter)
  • Capacity
  • Dependent on selected size and application
  • Diameter
  • 50 mm to 300 mm (varies by model)
  • Pressure
  • PN10 / PN16
  • Seal Type
  • Nitrile / EPDM
  • End Connection
  • Wafer design fits between ANSI 150/PN16 flanges
  • Testing Pressure
  • 1.5 x PN (Body), 1.1 x PN (Seat)
  • Usage
  • Prevents backflow in fire protection pipelines
  • Plate Material
  • Stainless Steel
  • Body Material
  • Cast Iron / Ductile Iron (variants available)
  • Flow Direction
  • Unidirectional (marked with arrow on body)
  • Corrosion Resistance
  • Yes, with corrosion-resistant body and springs
  • Opening Pressure
  • 0.2 bar (typical)
 
 

About DUAL PLATE NRV FOR FIRE LINE



Experience the meritorious reliability of the DUAL PLATE NRV FOR FIRE LINE, designed for fire safety systems. With its reduced pressure drop and fresh, corrosion-resistant cast iron/ductile iron body, this valve offers spectacular performance. Featuring stainless steel plates, advanced spring-loaded mechanisms, and nitrile/EPDM sealing, it ensures automatic, zero-leak shutoff in horizontal or vertical fire lines. Its wafer design supports quick installation between ANSI 150/PN16 flanges. Remarkably suitable for Class A, B, and C fire protection, this resilient valve offers a reduced maintenance profile and long-lasting, premium protection.

DUAL PLATE NRV FOR FIRE LINE: Features & Usage

This advanced wafer-type non-return valve offers premium corrosion resistance, low pressure drop, and rapid, automatic shutoff with its spring-loaded dual plates. Specifically designed for fire protection pipelines, it guarantees unidirectional flow and zero leakage, vital for fire-fighting systems and sprinkler lines. With in-line, wafer-type mounting, it adapts readily to both horizontal and vertical installations. Usage spans water and fire sprinkler pipelines, offering a remarkable solution for maintaining robust, consistent fire safety operations.


Sample Policy & Payment Terms for DUAL PLATE NRV FOR FIRE LINE

Samples for the DUAL PLATE NRV FOR FIRE LINE are available on an advance purchase basis, with premium delivery options to ensure prompt receipt. While a nominal sample charge may apply, the charges can be adjusted against larger orders upon confirmation. Payment terms are flexible and can be discussed with the supplier for bulk or repeated purchases. Our policy ensures fresh, well-packaged samples that truly represent the remarkable quality of the product delivered anywhere across India.


FAQ's of DUAL PLATE NRV FOR FIRE LINE:


Q: How does the DUAL PLATE NRV FOR FIRE LINE prevent backflow in fire protection pipelines?

A: The valve uses dual spring-loaded stainless steel plates and a reliable seal (nitrile/EPDM) to ensure unidirectional flow, closing automatically if flow reverses in fire protection lines, effectively preventing backflow.

Q: What are the primary benefits of using this NRV in fire-fighting and sprinkler systems?

A: Key benefits include reduced maintenance needs, quick shutoff to avert reverse flow, fresh design for low pressure drop, and meritorious corrosion resistance, making it spectacularly effective in safeguarding fire line integrity.

Q: Where can the DUAL PLATE NRV FOR FIRE LINE be installed?

A: It can be mounted in-line, wafer-type, between ANSI 150/PN16 flanges in horizontal or vertical pipeline orientations, providing flexible installation across diverse fire safety systems.

Q: What is the process for ordering and receiving a sample of this valve?

A: Simply contact the supplier, request a sample with advance purchase, and the premium-quality sample will be delivered promptly. A nominal charge may apply, which can be adjusted in subsequent orders.

Q: When is this valve recommended for use in fire application pipelines?

A: This NRV is highly recommended for use where automatic, quick shutoff is needed to prevent backflow, especially in vital fire-fighting and water sprinkler pipelines adhering to Class A, B, or C fire safety codes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire-fighting & Fire Protection Equipment Category

CO2 BOTTEL

CO2 BOTTEL

Price 1200 INR / Piece

Minimum Order Quantity : 100 Pieces

Features : Portable, Refillable, NonCorrosive

FIRE HOSE PIPE

FIRE HOSE PIPE

Price 1900 INR / Piece

Minimum Order Quantity : 1000 Pieces

Features : Good Quality

Usage : Safety

Material : SS

HYDRANT VALVE

HYDRANT VALVE

Price 1000 INR / Piece

Minimum Order Quantity : 100 Pieces

Features : Good Quality

Usage : Safety

Material : MS

Alarm : No

sprinkler fire

sprinkler fire

Price 1000 INR / Piece

Minimum Order Quantity : 100 Pieces

Features : Good Quality

Usage : Safety

Material : MS

Alarm : Yes



Back to top